Installation manual
HB-37420-810-01-25F-EN SMX100 Installation manual.docx
Page 58 of 260
Version: 25F
-
25C° … +70C° storage and transport
Class of protection
IP 20
Climatic category
3k3 acc. to DIN 60 721-3
Min-, Maximum relative humidity
(no condensation)
5% - 85%
EMC
EN 61000-6-2, EN 61000-6-4, EN 61000-6-7, EN
61800-3, EN 61326-3, EN 62061
Operating altitude
2000m
Overvoltage category
III
Degree of pollution
2
Mechanical data
Dimensions
(HxDxW [mm])
SMX112-2/112-2A
= 100x115x112,5
SMX112-2/112-2A(/2/D)
= 100x115x135
Weight
(g)
SMX112-2/112-2A
= 520
SMX112-2/112-2A(/2/D)
= 620
Mounting
To snap on top-hat rail
Number of T-bus connectors
SMX112-2/112-2A
5
SMX112-2/112-2A(/2/D)
6
Min. terminal cross-section / AWG
0,2 mm² / 24
Max. terminal cross-section / AWG
2,5 mm² / 12
(*)
maximal 2 Encoder / Axis
(**)
pn/pp are configurable via SafePLC2
(***)
Derating, see Chapter "Derating outputs"
(****)
Analogue electricity, voltage inputs are available as options
z.B.:
SMX12-2A-U (/2) Voltage inputs
SMX12-2A-I (/2) Electricity inputs
SMX12-2A
Voltage and electricity inputs
1)
Value applies only for extension module. For a total assessment in accordance with EN ISO 13849-1 one
must use a sries connection with the corresponding basic device
=> PFH
Logic
= PFH
Basic
+ PFH
Extension