Page
46
Country
Code:
DS62
MD4
ONLY
UNIT
RESET
LOGOUT
Select RU),
to reset the unit to the current configurations, the RPC will display:
Reset Unit? (Y/N)
NOTE:
A Unit Reset takes approximately 60 seconds for the unit to reset. It will not reset the
unit to “Factory Default”, but it will terminate all external communications.
Select T),
will close the session to the unit, but
may not
close the terminal emulator session.
Select 7) from the Modem Configuration Menu, this option sets the modem to recognize the countries
Telecomm Requirements, i.e. ring tone, dial tone.
Typical Country Code:
Argentina.....07 Australia......09 Austria........FD Belgium........FD
Brazil........16 Canada.........B5 Chile..........99 China..........B5
Czech Re......FD Denmark........FD France.........FD Germany........FD
Greece........FD Hong Kong......99 Hungary........FD Iceland........FD
India.........99 Indonesia......99 Israel.........B5 Italy..........FD
Japan.........00 Korea Re.......B5 Lithuania......FD Malaysia.......6C
Mexico........B5 Netherlands....FD New Zealand....7E Norway.........FD
Philippines...B5 Poland.........FD Portugal.......FD Romania........FD
Russian Fe....FD Singapore......9C Slovenia.......FD Spain..........FD
Sweden........FD Switzerland....FD Taiwan.........FE Thailand.......B5
Turkey........FD United Kingdom.FD United States..B5
Current Country Code is:B5
Change It ? (Y/N) :y
If you type ‘y’ to change the Country Code the
module will respond with the following:
Enter 2 digits Country Code : b5
Current Country Code is:B5
NOTE:
If your country code is not listed select a country code closest to your country.