Remote Annex 2000 Hardware Installation Guide
Chapter 4 Troubleshooting Procedures
4-4
Activity N2: Testing
the Hardware
During the power-up sequence, the Remote Annex 2000 runs a series
of self-test diagnostics. These tests verify internal hardware functions.
The Power LED lights for a few seconds, then Unit and Active LEDs
flash during the power-up self-tests. After the self-tests complete,
only the Unit and Power LEDs remain on.
Activity N3: Testing
the Network
The Remote Annex 2000 sends a short packet addressed to itself
through the transceiver to test the transceiver and its cable. After
passing this test, the Net LED flashes and remains on.
Activity N4: Looking
for the Boot File
The Load LED flashes while the Remote Annex 2000 waits for a load
server host to respond to its load request.
Activity N5:
Loading the Code
The Load LED lights while the Remote Annex 2000 loads its
operational code from a load server host.
If a port is set up for syslogging, the associated LED will flash
when data is output on the port, thus interfering with the
normal LED sequence.
Activity N6:
Running the
Operational Code
The Load LED turns off when the proper image is loaded. The
operational code has control, and the Remote Annex 2000 is ready.
Summary of Contents for Remote Annex 2000
Page 1: ...Part No 166 024 150 Rev C1 August 1996 Hardware Installation Guide Remote Annex 2000 ...
Page 4: ...Remote Annex 2000 Hardware Installation Guide Revision Level History iv ...
Page 8: ...Remote Annex 2000 Hardware Installation Guide Figures x ...
Page 10: ...Remote Annex 2000 Hardware Installation Guide Tables xii ...
Page 14: ...Remote Annex 2000 Hardware Installation Guide Preface xvi ...