![Baxi POWER HT+ 1.110 Installation And Service Manual Download Page 13](http://html.mh-extra.com/html/baxi/power-ht-1-110/power-ht-1-110_installation-and-service-manual_2711894013.webp)
Unit
POWER HT+
1.50
POWER HT+
1.70
POWER HT+
1.90
POWER HT+
1.110
Maximum absorbed power - Stand-by
W
2.7
3
3
3
Tab.5
Other characteristics
Unit
POWER HT+
1.50
POWER HT+
1.70
POWER HT+
1.90
POWER HT+
1.110
Electrical protection class
IP21
IP21
IP21
IP21
Weight empty
Kg
60
70
104
109
3.2.1 Sensor characteristics
Tab.6
Heating flow sensor and return sensor
Temperature (in °C)
30
65
85
Resistance (in ohms)
8060
2085
1070
3.3 Dimensions and connections
Fig.2
Dimensions and connections POWER HT+ 1.50 and POWER HT+ 1.70
600
440
247
848
56
681
212
420
65
905
586
555
440
371
271
147
98
173
(1)
MW-3000001
1
2
4
3
1 Heating circuit return (G1")
2 Heating circuit flow (G1")
3 Gas inlet (G3/4”)
4 Condensate discharge (DN18)
(1) Adjustable feet
3 Technical specifications
7609474 - v02 - 04092014
13