The control (1) is an electronically built-up 2-stage control. The 2 stages can be set according to the heat
requirement: 30-100%. It is also possible to make a setting for high or low output.
The boiler will run at a high output until the set temperature is close to being achieved.
Then the automatic control will switch to reduced output. If the temperature then drops slightly again, the
automatic control will couple up to full output again.
When the set temperature has been achieved, the blower will be switched off and the automatic control
will switch over to intermittent operation. This means that the fire is kept alight by adding a little fuel at
considerable intervals and simultaneously briefly setting the blower in action.
1.1.3 Service and guarantees:
The guarantee is described more closely in the BAXI Guarantee Certificate which is delivered together
with the boiler.
Complaints: You ought always refer to the fitter or dealer who has installed / delivered the central heating
boiler for you. After this, the fitter / dealer will, if necessary, pass on your complaint to the factory.
However, complaints can also be made directly to the factory.
1.2 Responsibility and safety
1.2.1 Responsibility The user is responsible for correct operation of the boiler and that the firing
guidelines from BAXI A/S are followed. Circumvention of the guidelines can, amongst other things,
result in a lower useful effect and increased environmental strain, as it is not possible to achieve the clean
smoke gases which are aimed at. Furthermore, incorrect operation can reduce the lifetime of the boiler.
Correct operation (and installation) are the best guarantee for a well-functioning boiler with a long
lifetime and a good immediate environment.
It is a precondition that the user has the necessary will and correct attitude to firing with wood pellets,
grain, maize, wood chips, and such like since, after all, it is necessary to carry a piece of work in order to
"harvest the fruits" of this environmentally friendly and economically advantageous form of heating.
1.2.2 Safety: If faults or deficiencies are ascertained, these must be rectified as quickly as possible by a
heating and ventilation fitter.
Outlet pipes, ventilation channels, fresh air openings, etc must not be closed or blocked.
The water supply for the boiler's retrograde combustion (back burn) safety device must not be shut off.
Inflammable liquids or easily combustible materials must not come dangerously close to the boiler.
All stoking must take place via the stoker system.
1.2.3 Maintenance: If irregularities on the system's safety valves, expansion tanks or automatics are
ascertained, the owner / user must immediately ensure that the equipment in question is examined and put
right by an expert.
The owner / user must ensure that fitted safety valves, if any, are not blocked up by incrustation and
suchlike.