Retrograde combustion safety device
inches
½
½
½
Tapping-faucet is fitted by the factory
inches
½
½
½
**) Minimum recommended stand-by output during intermittent operation during which the fire can be
maintained. In order to maintain the fire outside of the heating season there must always, as a minimum,
be a hot water tank as well as 1-2 radiators connected (open)..
***) These are the minimum smoke temperatures which are achieved by means of the approval with the
above mentioned 24-hour operation at minimum output. This smoke temperature is too low for ordinary
operation, with ordinary chimneys. We consider a smoke temperature of 100°C as being the absolute
minimum for ordinary chimneys. We have therefore built-in an alarm on the smoke temperature at 100°C.
This means that if the smoke temperature has been below 100°C for half an hour the boiler will stop. This
alarm function also ensures against continuing to feed fuel into the boiler, if the fire has gone out
Page 23
4.2 Electrical diagram
4.2.1 Panel
4.2.2 Multi Heat standard (400V)