![Baxi MULTI-HEAT Instructions For Installation And Use Manual Download Page 40](http://html.mh-extra.com/html/baxi/multi-heat/multi-heat_instructions-for-installation-and-use-manual_2711862040.webp)
Chips
kg pr hour
-
7,2
11
Gear motor effect
kW
0,12
0,37
0,37
Blower motor effect
W
90
90
90
Electricity consumption
kW
0,3
0,46
0,46
Electrical connection / fuse size
3 × 400 V + earth - 50 Hz /
10 A
1 × 230 V + earth - 50 Hz /
10 A
Setting for line circuit breaker 400V/230V
A
0,6
1,2
1,2
Approved fuel types
Wood pellets
approx. 8
% water
5-20 mm
5-20 mm
5-20 mm
Grain/Maize
approx. 15
% water
-
X
X
(see also section 1.1.1)
Chips (fine)
approx.
25% vand
-
X
X
Test pressure, boiler
bar
4,0
4,0
4,0
Test pressure, coil (extra equipment)
bar
25
25
Not
supplied
Flow and expansion
inches
1
1
1
Return
inches
1
1
1
Noise level
dB(A)
<70
<70
<70