![Baxi CBP Matic 18 Manual Download Page 235](http://html.mh-extra.com/html/baxi/cbp-matic-18/cbp-matic-18_manual_2711698235.webp)
72
- Troubleshooting
Troubleshooting
Maintenance “Service”
Air mass probe failure
Low pellet level
The door is open
Air temperature probe failure
Water temperature probe failure
Water pressure sensor fault
Water pressure close to being outside operating
range
Table6
-
List of anomalies
Important notice: The maintenance anomaly (the "service" message appears on
the display) indicates that the unit has exceeded 2100 operating hours. The unit must
be serviced; only then hour meter can be restarted (Technical menu) and the warning
cleared. This anomaly does not influence the normal operation of the boiler, it is
merely a warning.
Important notice: when the alarm “A16” is triggered, you can check the pressure
reading on the
unit. To do so, press the “Mode” button for 10 seconds to access the
standard menus. You have a 2-
minute window to access the “info usuario” (user info)
menu and check the pressure reading at the unit.
Important notice:
you can only reset error messages that are flashing on the
display. If the error message is steady on the display, press the "Mode" button once.
Important notice: the anomalies do not cause the unit to shut down.
WARNING!
In case of an emergency, switch the unit off using the standard shutdown procedure.
WARNING!
THE UNIT WILL BE HOT DURING OPERATION, SO YOU NEED TO BE
ESPECIALLY CAREFUL OF THE DOOR HANDLE.
Summary of Contents for CBP Matic 18
Page 14: ...11 Mín 2 m T Inspección a Min 4 m Min 1 m Máx 3 m Máx 2 m Incl 3 5 120 mm b ...
Page 78: ...75 Figura 66 Esquema eléctrico de la placa eléctrica del silo externo ...
Page 151: ...67 Figura 58 Retirar os parafusos do extractor e aspirar a zona de passagem do ar ...
Page 158: ...74 13 Esquemas eléctricos da Caldeira a pellets Figura 65 Esquema eléctrico placa electrónica ...
Page 159: ...75 Figura 66 Esquema eléctrico placa eléctrica do silo externo ...
Page 160: ...76 a b Figura 67 Sensores de nivel de pellets ...
Page 231: ...68 c b c d e f ...
Page 241: ...78 Figure 68 Electrical diagram of the external silo s circuit board ...
Page 245: ...82 ...
Page 246: ...83 ...
Page 247: ...84 ...
Page 248: ......
Page 249: ...86 BAXI Tel 34 902 89 80 00 www baxi es informacion baxi es ...