a)
b)
Figure 28
– Adjustment of the sensors sensitivity
- If the light do not go out when moving the sensor away from the pellets or do not
come on when approaching, re-adjust the sensitivity of the sensor and repeat the
test.
-
You shall perform the sensitivity adjustment for both the boiler’s tank level sensors
and for the storage unit’s level sensor.
You can also adjust the sensor's response time, to set the time the sensor waits
before sending the signal to the circuit board upon detecting the pellets. This setting
can be made directly on the storage unit electronic circuit board, on the upper right
corner, using the same procedure used for adjusting the sensitivity
– rotate clockwise
to increase the response time and counter clockwise to decrease the response time.
The response time should be set to the minimum value
Installing the storage unit on the right side of the boiler
The level sensor of the storage unit must always be installed on the side closest to
the boiler.
1
– If you want to install the storage unit on the right side of the boiler you must install
the level sensor on the left side of the storage unit, in the same place where he
comes assembled by default. Before, you should disconnect the plug of the cable
connected to the circuit board, to facilitate the assembly. To fasten it, you should use
the screws previously removed, and put it in the position shown in Figura 29-b.
Summary of Contents for CBP Matic 18
Page 14: ...11 Mín 2 m T Inspección a Min 4 m Min 1 m Máx 3 m Máx 2 m Incl 3 5 120 mm b ...
Page 78: ...75 Figura 66 Esquema eléctrico de la placa eléctrica del silo externo ...
Page 151: ...67 Figura 58 Retirar os parafusos do extractor e aspirar a zona de passagem do ar ...
Page 158: ...74 13 Esquemas eléctricos da Caldeira a pellets Figura 65 Esquema eléctrico placa electrónica ...
Page 159: ...75 Figura 66 Esquema eléctrico placa eléctrica do silo externo ...
Page 160: ...76 a b Figura 67 Sensores de nivel de pellets ...
Page 231: ...68 c b c d e f ...
Page 241: ...78 Figure 68 Electrical diagram of the external silo s circuit board ...
Page 245: ...82 ...
Page 246: ...83 ...
Page 247: ...84 ...
Page 248: ......
Page 249: ...86 BAXI Tel 34 902 89 80 00 www baxi es informacion baxi es ...