![Baxi CBP Matic 18 Manual Download Page 169](http://html.mh-extra.com/html/baxi/cbp-matic-18/cbp-matic-18_manual_2711698169.webp)
6
3.
Technical specifications
FEATURES
CBP Boiler 18
kW
CBP Boiler 24
kW
CBP Boiler
30kW
Units
Weight
350
350
350
Kg
Height
1300
1300
1300
mm
Width
677
677
677
mm
Depth
1110
1110
1110
mm
Diameter of the fume discharge pipe
100
100
100
mm
Reservoir capacity
45
45
45
Kg
Maximum heating capacity
425
545
680
Maximum thermal power (water)
18
24
29
kW
Minimum thermal power (water)
6
6
6
kW
Minimum fuel consumption
1.3
1.3
1.3
Kg/h
Maximum fuel consumption
4.4
5.3
6,1
Kg/h
Rated electrical current
150
150
150
W
Electric power at start-up (<10 min.)
450
450
450
W
Rated voltage
230
230
230
V
Nominal frequency
50
50
50
Hz
Thermal yield at rated thermal power
90
90.2
90.4
%
Thermal yield at reduced thermal
power
87,8
87,8
87,8
%
Max. gas temperature
102,4
112
121.6
ºC
Min. gas temperature
74.1
74.1
74.1
ºC
CO emissions at rated thermal power
0.010
0.015
0.019
%
CO emissions at reduced thermal
power
0.026
0.026
0.026
%
Draught in the chimney
12
12
12
Pa
Unit water volume
60
60
60
W
Fume extractor sound level
67,6
67,6
67,6
dB(A)
Table 4
– Technical specifications
Summary of Contents for CBP Matic 18
Page 14: ...11 Mín 2 m T Inspección a Min 4 m Min 1 m Máx 3 m Máx 2 m Incl 3 5 120 mm b ...
Page 78: ...75 Figura 66 Esquema eléctrico de la placa eléctrica del silo externo ...
Page 151: ...67 Figura 58 Retirar os parafusos do extractor e aspirar a zona de passagem do ar ...
Page 158: ...74 13 Esquemas eléctricos da Caldeira a pellets Figura 65 Esquema eléctrico placa electrónica ...
Page 159: ...75 Figura 66 Esquema eléctrico placa eléctrica do silo externo ...
Page 160: ...76 a b Figura 67 Sensores de nivel de pellets ...
Page 231: ...68 c b c d e f ...
Page 241: ...78 Figure 68 Electrical diagram of the external silo s circuit board ...
Page 245: ...82 ...
Page 246: ...83 ...
Page 247: ...84 ...
Page 248: ......
Page 249: ...86 BAXI Tel 34 902 89 80 00 www baxi es informacion baxi es ...