LIGHT SWITCH AND MICRO SWITCH
For either of these operations the bezel is
first removed.
TO REMOVE THE BEZEL :-
Ensure that the electricity supply to
the fire unit is isolated.
Remove the control knob by pulling it
from the spindle.
Undo the screw securing the bezel. From the inside of
the chassis depress the two upper retaining barbs and
ease the bezel outwards.
TO CHANGE THE LIGHT SWITCH :-
Remove the two spade connectors from the switch.
Press together the two retaining arms on the
rear of the switch to release it from the
bezel.
Fit the new switch to the bezel, ensuring
that the OFF position will be towards the
front of the fire. Reconnect the spade
connectors to the new switch.Replace the
bezel and control knob.
TO CHANGE THE MICRO SWITCH :-
Disconnect the two spade connectors from the micro
switch.
Release the micro switch and spring from
the gas tap spindle by removing the circlip.
Discard the old micro switch and fit the
new one onto the gas tap spindle,
remembering to first replace the
spring.
Reconnect the spade connectors to
the micro switch. Replace the bezel
and control knob.
Spade Connectors
Retaining Barbs
28