CONNECTING THE FIRE ELECTRICAL SUPPLY CABLE
TO THE BOILER
If the boiler electrical connections have already been
made, ensure that the electrical supply to the boiler is
isolated. The fire should always be electrically
connected as described below and must not be
provided with an electrical connection that is
independent from the boiler.
The wires from the socket and cable assembly, that
are supplied with the fire unit, should be connected
into the boiler electrical supply socket as follows :-
Connect the blue wire (neutral) to the remaining
terminal marked "N".
Connect the brown wire (permanent live) to the
remaining terminal marked "L2".
Route the green and yellow wire (EARTH) through
the cut-out in the socket housing and connect it to
the earth terminal on the boiler base tray.
NOTE:- The earth wire should be sufficiently
long, so that if the supply cable is pulled on,
the live and neutral wires will become taut before
the earth wire.
Using the cable clamp with the flat side
downwards, secure the cable in the socket.
Refit the socket cover and fix it in place with
the screw.
Refit the socket to the boiler base tray and secure in
place with the securing screw.
Reconnect the controls connection plug to the
socket and secure it in place using the
securing screw.