GAS CONTROL TAP AND PILOT FILTER
Ensure that the electricity and gas supply to the
fire unit is isolated.
Remove the two fixing screws that secure the fire
top panel to the chassis and lift the panel at the
front to release it from the fire.
Remove the cover that shields the micro switch
and light switch electrical connections by
releasing the single retaining screw and drawing
the cover forward.
Remove the control knob by
pulling it from the spindle.
Undo the screw securing the bezel. From the inside of
the chassis depress the two upper retaining barbs
and ease the bezel outwards.
Disconnect the two electrical connections from the
micro switch.
Release the thermocouple from the gas control tap
by unscrewing the small retaining nut.
Release the gas pipes that are connected to the gas
tap by unfastening the compression nuts.
NOTE:- The small diameter pipe is the pilot
feed pipe. The pilot filter is situated in the gas
tap at the end of this pipe.
On reassembly ensure that the new pilot filter
supplied with the replacement tap is fitted.
Remove the gas tap retaining nut and withdraw
the gas tap from the fire.
If the pilot filter has not already been removed,
it can be removed at this stage.
Replace the gas control tap in the reverse
order of removal.
Pilot Filter
Fire Top Panel
Fire Top Panel
Thermocouple
Pilot Feed Pipe
Retaining Nut That
Fastens Gas Tap
To Bracket
Retaining Barbs
29