4.1 Electrical Supply & Connection
1. All extemal wiring to the appliance must be in accordance
with the latest I.E.E. Wiring Regulations and any local
regulations that apply.
2. Ensure that any cables are not pulled tight and that it is
possible to isolate the electrical supply to the fire for
servicing.
3. In the event of an electrical fault after installation of the
appliance, preliminary electrical system checks must be
carried out i.e. earth continuity, short circuit, polarity and
resistance to earth.
4. Fuses used in this installation must be ASTA approved to
BS 1362.
5.
The appliance must be earthed.
6. Any additional cable used should be 0.75 mm
2
(24 x
0.2mm) PVC heat resistant as specified in table 16 of BS
6500.
7. Where the cable passes through brickwork or similar it
should be suitably protected and sealed.
8. This appliance requires a suitable 230 ~ 50Hz supply to
the fan box. The supply lead should be routed to a suitable
socket inside the house. If this lead is not long enough it may
be removed from the plug and a new cable fitted and wired
to a 3 A double pole isolating switch with a contact
separation of at least 3mm in both poles or to a 3 pin plug
which should also be fused at 3 A. This plug or isolating
switch should be readily accessible to the user to enable the
electrical supply to be switched off as required.