31
10.0
Annual Servicing - Page 30
10.5 Cleaning the Electrode
(Figs. 54 & 55)
1. Check for any signs of cracking or other damage to the
ceramic.
2. Clean the electrode wire if necessary.
3. Upon re-assembly check the spark gap is 2.5-4.0mm.
10.6 Cleaning the Fan
1. From outside remove the terminal guard and fan box
cover (Fig. 57).
2. Undo the screws holding the fan outlet plenum to the fan
box. Manouvre the plenum from the box taking care not to
damage the rear gasket (Fig. 56). Note the position of the
three wires to the fan and remove them. Disconnect the
sensing tube from the fan (Fig. 58).
3. Rotate the complete fan approximately 20º anti-clockwise
to disengage it from the fan box. Draw the fan clear of the
box (Fig. 58).
4. Ensure the flue duct is clean and free from debris.
5. Carefully clean any deposits from the fan impellor with a
soft brush.
6. When reassembling ensure that the rear gasket is in
position behind the flue outlet plenum.
10.7 Completing Servicing
1. Clean any dirt and debris from the appliance combustion
box and installation.
2. Reassemble all components in reverse order of
dismantling and recommission the fire.
Summary of Contents for Belmont 2
Page 7: ...7 ...
Page 11: ...11 4 0 Electrical Page 10 4 2 Schematic Wiring Diagram ...