21
5.0
Installation - Page 20
5.6 Fitting the Fire
(cont)
CABLE TENSION METHOD OF FIXING
1. Engage the tensioning nuts on the threaded shanks of
the tensioning devices. Run the nuts down to the hexagonal
heads of the tensioning devices (Fig. 29).
2. From the front insert the cable tensioning devices through
the combustion box rear panel. The hexagonal heads must
be to the inside of the box (Fig. 29).
3. Fit the fan box harness through the hole at the right hand
side of the fire. Do not draw any more of the harness into the
fire than is necessary.
4. Position the appliance in front of the fireplace opening
and insert the cables in the holes in the combustion box rear
flange (Fig. 30). Pass the cables through the eyebolts in the
fire opening rear face and insert them in the tensioning
devices (Fig. 29 & 30). Manouvre the appliance backwards
into the opening, drawing any slack length of cable through
the tensioners.
5. Push the appliance as far back in the opening as possible
and pull the cables through the tensioners as tight as
possible.
6. Run the solderless nipples down the cables to the
tensioners and tighten their securing screws (Fig. 29). As
required, take the relevant grommet(s) and slide over the
gas and/or electrical supplies. Run the grommet(s) down the
pipe and/or cable and insert in the hole in the rear panel
(Fig. 31).
7. Using a suitable spanner tighten the tensioning nuts
clockwise so that the fire frame surround is pulled up against
the wall or surround and the seal is compressed.
DO NOT
CUT OFF THE EXCESS CABLE
- coil neatly and secure
with tape.
8. Fit the gas inlet/pressure test point elbow supplied in the
kit to the controls feed pipe (Fig. 31a). Connect the 8-way
plug to the controls and secure the earth lead to the earth
post on the fire. Connect the gas supply to the gas
inlet/pressure test point elbow and refit the burner chassis
(Fig. 31).