Changing Components - Page 21
Baxi Arena Super
When changing components ensure that the gas and
electricity supplies are isolated before the work is started.
Before changing any components please read the Important
Information section on page 3.
To change the GLASS FRAME, FRAME SEALING ROPE,
COAL BED, BURNER, INJECTORS and LIGHT SWITCH,
remove the canopy and side doors as shown.
To change a LIGHT BULB refer to the User’s Instructions for
this appliance.
To change the ELECTRODE LEAD, SPARK GENERATOR
and RESISTOR, remove the canopy, side doors and hearth
as shown.
To change the CONTROL TAP, PILOT / ELECTRODE /
THERMOCOUPLE ASSEMBLY, ELECTRO-MAGNETIC
UNIT and MICRO-SWITCH, remove the canopy, side door
hearth and electrical cover. The fire must then be
disconnected from the gas supply and removed from the fire
place to give access to the rear of the unit as follows:
1. Isolate the gas supply.
2. Disconnect the 3-pin plug from the socket beneath the
fire.
3. Disconnect the inlet pipe from the fire inlet.
HEARTH MOUNTING
Pull the fire forward until the flue spigot is clear of the closure
plate and lift away.
WALL FIXING
4. Remove and retain the screws securing the fire to the
wall mounting brackets.
5. Whilst holding the fire in position, remove and retain the
screws securing the fire to the
backing plate.
Pull the fire forward until the flue spigot is clear of the closure
plate and lift away.