PART# TC54.NG04C2
For TC54 Series C

IMPORTANT:
THESE INSTRUCTIONS ARE TO REMAIN 
WITH THE  HOMEOWNER

These instructions are supplementary to the Installation 

and Operating Instructions supplied with the fi replace 

and should be kept together. Refer to the  Installation 

and Operating Instructions for proper gas supply, safety 

requirements and operating instructions.

TC54 
TRANQUILITY 
BURNER KIT 
INSTRUCTIONS

070211-16                                                                          TC54.NG04C2                                                                             5056.4256204

Summary of Contents for TC54.NG04C2

Page 1: ...are supplementary to the Installation and Operating Instructions supplied with the fireplace and should be kept together Refer to the Installation and Operating Instructions for proper gas supply safety requirements and operating instructions TC54 TRANQUILITY BURNER KIT INSTRUCTIONS 070211 16 TC54 NG04C2 5056 4256204 ...

Page 2: ...A BURNER ASSEMBLY B PEBBLE ASSEMBLY C 7lbs SAND D LINE COVER LEFT E LINE COVER RIGHT F PKG TAPERED PLUGS not shown TC54 NGO4C2 070211 16 B C A E D K 2 Contents of Package ...

Page 3: ... to ensure proper connection Nylon zip ties must be removed after connections have been made and prior to ignition NOTE If unit is to be converted to Propane see Propane conversion instructions on page 7 before proceeding NOTE Plug the 4 vacant holes in the bottom of the firebox with 1 2 screws as they are not required to attach this style of burner NOTE Due to the size of this unit it is highly r...

Page 4: ...ot white end to the connector marked by the white dot Fig 5b Repeat for the rear valve 8 Repeat this process with the remaining manifold and the pilot assembly provided with the burner kit 9 Install right side panel as per panel installation instructions and finalize setting burner assembly into the unit Fig 6 10 Slide the line covers out from under the burner tray and slip the tab into the slot i...

Page 5: ...not to let sand enter pilot locations Fig 9 13 Brush the sand smooth and gently blow excess sand from around burner ports before removing the tapered plugs Fig 10 CAUTION Before pouring sand ensure all connections and adjustments are made Removing sand is very difficult TC54 NGO4C2 070211 16 Fig 8 Fig 9 Fig 10 PLUGGING PORTS WITH TAPER PLUGS SAND PLACEMENT SAND FINISHING 5 ...

Page 6: ...Fig 11 15 Place four trim rocks approx 2 dia in spaces between the pebble assemblies to fill the gaps Do not place rocks on top of the assemblies Fig 12 and 13 16 Place the remaining four trim rocks at desired locations around the pebble assemblies Do not place rocks on top of the assemblies Fig 13 TC54 NGO4C2 070211 16 Fig 11 Fig 12 Fig 13 INSTALL PEBBLE ASSEMBLY INSTALL TRIM ROCKS INSTALL TRIM R...

Page 7: ...he appliance has cooled 2 Remove three screws holding down the burner tray and lift off the tray sliding slightly forward to disengage from both orifices Fig 14 3 Usinga1 2 wrench removebothnatural gas burner orifices marked 29 Fig 15 4 Apply a small amount of pipe joint com pound to the threads of the propane burner orifice marked 44 to ensure a good seal before screwing it into the fitting 5 Ope...

Page 8: ... a wrench 7 Slide the pilot adjustment band over and ensure that the hole in the orifice band is showing Fig 18 indicates NG position Fig 19 indicates LP position Retighten the pilot head Replace the pilots and burner tray Ensure the burner inlets engage both burner orifices TC54 NGO4C2 070211 16 Fig 17 Fig 18 Fig 19 8 ...

Page 9: ...screwdriver to back the screw out to the limit of the threads A groove on the screw body will be visible just above the valve body Insert a thin tool knife blade or thin screw driver blade into the groove and gently pry the screw up It helps to rotate the screw while lifting on it Caution The center post must be up for natural gas and down for propane for the ap pliance to operate correctly LP GAS...

Page 10: ...red to ensure a gas tight connection Note To test the gas pressure turn off the gas supply before removing the plug from the supply pressure test port or manifold pressure test port Verify gas pressures with the fireplace lit and on the highest setting Correct gas pressure requirement Supply Pressure Natural Gas Propane Min Pressure 5 0 WC 12 5 WC For purpose of input adjustment Max Pressure 13 9 ...

Page 11: ...rnal parts and window glass The air shutter on the burner tube controls the primary combustion air to the gas burner The shutter should be set to fully closed for natural gas or fully open for propane See Fig 28 for proper plame pattern TC54 NGO4C2 070211 16 Fig 28 11 Burner Flame Adjustment ...

Page 12: ...5025B 4 ORIFICE NG 29 2 Required 5022 135 5 MANIFOLD SUPPLY TUBE 5019 223 6 PEBBLE ASSEMBLY TC54 9499 7 PROPANE CONVERSION KIT TC54 LPCE01 8 7lbs SAND 2 Required TC42 SAND34 WHEN ORDERING INCLUDE PART NUMBER WITH DESCRIPTION NOT SHOWN TC54 NGO4C2 070211 16 1 2 4 3 1c 1f 1g 1b 1a 1e 1d 1j 1h 1i 12 TC54 Tranquility Burner Replacement Parts ...