background image

EN • 1

662Y0600 • A

E

N

FR

R

U

P

L

DE

IT

ES

N

L

INSTALLATION, OPERATING AND 

SERVICING INSTRUCTIONS

25 - 35 - 45 - 55

60 - 70 - 100

BG 2000-S

BG 2000-S

(V13)

(V13)

Summary of Contents for BG 2000-S 100

Page 1: ...EN 1 662Y0600 A EN FR RU PL DE IT ES NL INSTALLATION OPERATING AND SERVICING INSTRUCTIONS 25 35 45 55 60 70 100 BG2000 S BG2000 S V13 V13...

Page 2: ...70 5 BG 2000 S 100 6 12 ELECTRODES ADJUSTEMENT BURNER COMPONENTS 7 FITTING THE BURNER 13 DIMENSIONS SERVICING THE BURNER 3 WARNINGS 9 FAN SETTING PROCEDURE 16 PROPANE CONVERSION Assembling and dismant...

Page 3: ...l before installing and bringing the boiler into service It is prohibited to modify the interior of the appliance in any way without the manufacturer s prior written agreement The product must be inst...

Page 4: ...ch will set the CO2 in the flue gas A given output can then be set simply by adjusting the speed of rotation of the fan and the CO2 to preset values LIGHTING AND FLAME CONTROL The burner control unit...

Page 5: ...ri 5 Burner chamber plate seal 6 Burner chamber plate insulation 7 Ionisation electrode 8 Fan 9 Burner chamber plate 10 Flame inspection window 11 Burner plug 12 Potentiometer setting 13 Fan power plu...

Page 6: ...electrode 3 Gas valve 2x 4 Venturi 2x 5 Burner chamber plate seal 6 Burner chamber plate insulation 7 Ionisation electrode 8 Fan 9 Flame inspection window 10 Burner chamber plate 11 Burner plug 12 Pot...

Page 7: ...EN 7 662Y0600 A EN FR RU PL DE IT ES NL 1 3 5 2 4 6 7 8 Fitting the burner Adjust the CO2 see page 8...

Page 8: ...uch this screw Warning To respect the parameters of the offset adjustement mentioned again in the table above Gas flow rate Venturi gas valve 4 2 1 3 G20 G25 G31 Burners Boilers Output kW CO2 Rpm max...

Page 9: ...otection of the fan 1 Remove the green protective disk 2 Release the clips of the fan motor cover 4 Adjust the speed of the fan using the settings in the table underneath rotate counter clockwise to r...

Page 10: ...000 S See also installation manual HeatMaster 30 N 60 N 70 N Burner wiring BG 2000 S 25 35 45 55 60 70 Y Gr Br B Bk R Bk Br Br B Br Bk Y Gr R B 3 2 1 2 1 2 3 4 5 6 7 8 9 10 6 7 8 9 10 1 2 3 4 5 1 2 3...

Page 11: ...ee also installation manual HeatMaster 100 N Burner wiring BG 2000 S 100 Y Gr Br B Br B Br V B Y Gr Br 3 2 1 6 T2 S3 T1 N L1 B4 230 V 50HZ Bk V B Y Gr Bk Br Br Br B B B Y Gr Y Gr Y Gr T2 S3 T1 N L1 B4...

Page 12: ...lve Honeywell VK4115V2038U BG 2000 S 25 35 45 55 60 70 537D4073 VK4115V1014B BG 2000 S 100 537D4009 Venturi Honeywell VF 002 45900444 002B BG 2000 S 25 35 HM 30 N 537D4034 VF 001 45900444 001B BG 2000...

Page 13: ...ange them if necessary 2 Check the condition of the flame holder E 3 Refit the burner and check that the burner lights 4 Check the gas connection for leaks 5 Ensure correct combustion Dimensions BURNE...

Page 14: ...ot enough water in the system 9 Radiator valves closed 10 Air in the system not vented properly 9 Gas pressure insufficient 11 Gas pipe too small 11 Boiler thermostat is faulty 12 Electrical system no...

Page 15: ...es or adjust thermostatic valves 10 Check that pipes and meter are suitable for the system 11 Replace boiler thermostat 12 Ensure electrical system complies with the regulations 13 Change fuses and fi...

Page 16: ...he fan 2 Torx screws see fig 2 5 Remove the venturi from the valve 3 Torx screws fig 3 6 Fit the right diaphragm see table on page 3 to the centre of the joint of the valve and the venturi fig 4 7 Ref...

Page 17: ...ax BG 2000 S 25 Delta Performance 25 25 0 9 0 3400 11 0 11 2 3100 Delta Pro 25 BG 2000 S 35 Delta Performance 35 34 9 9 0 4150 11 0 11 2 3760 Alfa Sprint S SV HeatMaster 30 N BG 2000 S 45 Delta Perfor...

Page 18: ...EN 18 662Y0600 A EN FR RU PL DE IT ES NL...

Page 19: ...EN 19 662Y0600 A EN FR RU PL DE IT ES NL...

Page 20: ...EN 20 662Y0600 A EN FR RU PL DE IT ES NL...

Reviews: