Light Switch
Ensure that the electricity supply to the fire unit is
isolated.
Remove the control knob by pulling from the spindle.
Remove the two screws holding the bezel in place.
Note the orientation of the two electrical connections and
disconnect from the switch. Remove the bezel.
Press together the retaining arms on the rear of the switch
and remove from the bezel.
Fit the new switch in place, ensure that the orientation of the
switch is correct. (i.e. with the ‘O’ symbol towards the front of
the fire.) and make good the electrical connections.
Re-assemble the components in the reverse order to
dismantling.