Supplied By www.heating spares.co Tel. 0161 620 6677
17
Annual Servicing - Page 17
Disconnect the 3-pin plug from the socket beneath the fire.
Isolate the gas supply.
Disconnect the fire inlet pipe from the fire inlet.
HEARTH MOUNTING
Pull the fire forward until the flue spigot is clear of the closure
plate and lift away.
Inspect the fireplace for damage and blockages.
WALL FIXING
Remove and retain the screws securing the fire to the wall
mounting brackets.
Whilst holding the fire in position, remove and retain the
screws securing the fire to the backing plate. Pull the fire
forward until the flue spigot is clear of the closure plate and
lift away.
Inspect the fireplace for damage and blockages.