5. GENERAL INSTALLATION REQUIREMENTS
5.1
The appliance can be installed into the following :-
a)
A minimum 4.5in rebate surround or Baxi Fires Division 5in. spacer kit Part No
0595121. Where either of these are mounted to a combustible wall make sure that there
is no combustible material or combustible cladding in the area indicated on the wall
fixing template.
b)
A 2in rebate surround in conjunction with the Baxi Fires Division 3in. spacer kit
Part No 0595131. Where the surround is mounted to a combustible wall make sure that
there is no combustible material or combustible cladding in the area indicated on the
wall-fixing template.
c)
Recessed into a builder’s opening or cavity of a non- combustible wall. The cavity
can be elevated. The minimum cavity size is shown in figure 2. A lintel may be required
above the recess opening. If in doubt seek expert building advice. Lintel construction
details are given in section 8 of this guide.
This appliance must not be recessed into a
combustible wall
5.2
Note that soft wall coverings (e.g. embossed vinyl etc.) are easily affected by heat.
They may therefore, scorch or become discoloured when close to a heating appliance.
Please bear this in mind when installing.
Page 9
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2007.
Figure 2. Recess and flue hole dimensions