5.14
A terminal guard is supplied with this appliance.
In England and Wales the Building Regulations
require a terminal guard to be fitted if the
terminal could come into contact with people
near the building or be subject to damage.
In the republic of Ireland the installation must
also conform to the relevant parts of the current
edition of IS 813 “Domestic Gas Installations”
We recommend that the guard is fitted where
contact with or damage to the terminal is
possible even if regulations do not demand it.
5.15
If the fire is to be fitted against a wall with
combustible cladding, the cladding must be
removed from the area shown in figure 3.
5.16
Minimum allowable distances from the terminal are shown in figures 4a and 4b.
Page 13
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2007.
Figure 3. Area to be free of
combustible cladding.