15. FASCIA FITTING
!
Remove any protective film from the fascia.
!
Locate the two lugs at the top of the fascia in the slots
in the convection box hood. Swing the bottom of the fascia
sides back against the convection box and lower the fascia
so that the lugs are fully seated in the slots in the
convection box hood (See figure 29).
!
Refit the two screws to secure the bottom of the fascia
sides to the convection box side brackets.
Sonnet and Ultimate fascia.
!
Fit the fire front casting between the fascia sides. Locate
the two screw heads at the rear top corners of the casting
through the keyhole slots at the inner sides of the
fascia. If the screw heads do not project enough
or project too far, the screws can be adjusted.
Lower the casting so that it rests on the hearth
(See figure 30).
!
Place the bottom front cover casting in
position below the fire front casting.
Camden and Seattle fascia.
!
Secure the knob to the front of the fire front
with the screw supplied.
!
Fit the fire front between the fascia
sides. Locate the two hanging brackets at
the rear top corners of the casting through
the keyhole slots at the inner sides of the
fascia. Lower the fire front so that it rests
on the hearth (See figure 31).
Page 31
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2007.
Figure 31.
Figure 30.
Figure 29. Fascia fitting