6.2 Appliance disassembly.
Fascia removal
(See figure 5).
!
Remove the two screws securing the bottom of the
fascia to the sides of the convection box.
!
Raise the fascia to allow the retaining lugs at the top to
clear the slots in the convection box hood and then lift
clear.
!
Place the fascia in a safe place
away from your immediate work
area.
Window and ceramic fuel effect
removal.
!
Unscrew and remove the three
spring loaded window fixing screws
and washers from the base of the
window frame (See figure 6). Keep
the screws and washers in a safe
place.
!
Gently swing the base of the
window frame forward while lifting
the frame upwards. The window
should lift clear of the fire. Put the window in a safe
place away from your immediate work area.
!
Carefully remove the ceramic fuel effect in its
packaging. The ceramic fuel effect base is a single
piece. The individual ceramic pieces are packed
separately. Put them in a safe place.
6.3 Preliminary checks.
Check ignition spark
(See figure 7).
The pilot burner and electrode unit is at the left front
corner of the burner.
Push in the right hand control knob and turn
anticlockwise through the ignition position marked
and up to the pilot position marked
.
A spark should flash across from the pilot electrode to the pilot burner hood. If there is
no spark, check that the spark gap is as shown.
Page 16
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2007.
Figure 7. Ignition
Figure 6. Window
removal
Figure 5. Fascia removal