13. WINDOW FITTING
Fitting the window.
!
Locate the channel at the top of the window over the top of the firebox opening.
!
Refit the three spring loaded screws and washers. Tighten sufficiently to seal the
firebox.
!
Pull the bottom of the window forward and release to check that the window
opens slightly and returns in the event of a delayed ignition explosion
.
14. FULL OPERATING CHECKS
14.1 Check for leaks.
!
Turn on the gas supply and check all joints up to the appliance gas tap for gas
soundness using a soap solution or leak detection fluid.
14.2 Check control operation.
If the fire is turned off or the flames go
out, wait at least 3 minutes before
attempting to relight. A safety device in the
control stops the fire being turned back on
until it is safe
.
(
See figure 27).
!
Turn the left hand control knob fully
clockwise
!
Push in the right control knob and, while
keeping it depressed, turn anticlockwise
through the ignition position marked
and up to the pilot position marked
.
The spark should light the pilot. The pilot flame can be seen by looking through the gap
near the left side of the ceramic fuel effect front.
If the pilot does not ignite, keep the knob depressed for a few seconds to purge air from
the supply pipes. Then turn back to the off position marked
•
and repeat the ignition
procedure.
When the pilot has lit, keep the right hand control knob depressed for a few seconds to
allow the pilot flame to stabilise then release it. If the pilot does not remain alight
ensure that the air has been purged.
Partially depress the right control knob and turn to the main burner position
marked
. The main burner should now light at its low position.
Page 29
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2007.
Figure 27. Control