8.6 Prepare appliance fixing holes.
8.6.1 Screwing case to wall.
!
Recheck the position of the screw fixing holes
relative to the flue hole.
!
Drill the four fixing holes to a minimum depth of
42mm using a 7mm diameter masonry drill.
!
Insert four plastic wall plugs supplied.
8.6.2 Using cable retention.
!
Thread the two tension cables through the
appliance case side holes as shown in figure 11.
!
Move the appliance towards the recess and mark on
the recess back wall the position for the two eyebolt
holes.
!
Remove the appliance and drill at the marked
positions using a no.12 masonry drill.
!
Insert the two fibre wall plugs supplied.
!
Fit the two eyebolts.
Page 21
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2007.
Figure 11. Cable retention
Figure 10. Timber frame wall preparation