29
Operating Instructions Option Module IEI for b maXX drive PLC BM4-O-
IEI-01
6
C
OMMISSIONING
In this chapter, we will describe how you commission the IEI option module that you just
assembled and installed (see
from page 21 onward). Com-
missioning ensures that the IEI option module functions correctly. For more information
on programming, refer to the "b maXX drive PLC Application Manual".
Before starting commissioning, ensure that the following conditions have been met:
1
The plug-in module has been assembled correctly.
2
The plug-in module has been installed correctly.
3
The cabinet is closed correctly and all the safety devices have been started up.
4
The b maXX basic unit is ready for use.
6.1
General safety regulations
h
6.2
Requirements of the personnel carrying out work
Commissioning work must only be carried out by trained specialists who have understood
the safety regulations and information and can implement them.
6.3
Description/inspection of the safety and monitoring systems
Before you commission the IEI option module, you must eliminate any errors/error mes-
sages that may be present on the b maXX 4400 basic unit. These errors may be due to
DANGER
The following
will occur
,
if you do not observe this danger information:
m
serious personal injury
m
death
Danger from:
mechanical effects.
At commissioning, the drive can rotate.
Keep far enough the rotating parts. Note that when drives are starting up machine parts can