Technical Data
Operating Instructions Option Module IEI for b maXX drive PLC BM4-O-IEI-
01
85
D
D.2
Front panel
Figure 20:
BM4-O-IEI-01 front panel
D.2.1 Pin assignment of female Sub-D connector
Connection cable available (see
Pin No.
Assignment
1
M5V (Ground supply of encoder)
2
+5 V (Supply of encoder)
3
Encoder zero track
4
Encoder zero track inverted
5
Encoder channel 2
6
Reserved
7
Encoder channel 1 inverted
8
Encoder channel 1
9
Encoder channel 2 inverted
10
Reserved
11
Reserved
12
Alarm, wire break
13
Reserved
14
Reserved
15
Reserved