Assembly
Operating Instructions Option Module IEI for b maXX drive PLC BM4-O-IEI-01
Document No.: 5.02013.02
Baumüller Nürnberg GmbH
24
5.4
2
Pull the cover forward from the controller section: you can now see the slots.
3
Look for the intended slot (
G
) on the controller section.
Figure 7:
Assembly
4
Turn the spagnolet locks above and below this slot by 90°. The spagnolet locks are
now horizontal.
5
Take out the front panel cover forward. Keep this cover. If you remove plug-in cards,
you must close the unit again using the cover.
6
Observe the described ESD measures when handling the modules.
7
Remove the IEI option module from the transportation packaging: Avoid contact with
the plug-in module's electronic components.
DANGER
The following
will occur
,
if you do not observe this danger information:
m
serious personal injury
m
death
Danger from:
electricity.
The unit and the vicinity of the control cabinet may carry dangerous
voltages.
Before starting any work, ensure that the unit and its vicinity are free of voltage. Observe the
relevant safety regulations when handling current-carrying units.
CAUTION
The following
may occur
,
if you do not observe this caution information:
m
property damage.
Danger from:
electrostatic discharge.
The
IEI-01
i
ncremental encoder interface contains
ESD components.
Observe the described ESD measures when handling the plug-in module.
Only hold the plug-in module by the gripping piece (see "C" in