Operating requirements
Operation manual
b maXX
BM4100 (NWR)
Document no.: 5.04052.09
Baumüller Nürnberg GmbH
28
3.3
3.3.3
Required environmental conditions
1)
For the operation in an environment of category C2 according to IEC 61800-3:2005, additional measures may be required.The manu-
facturer of the installation / user must provide the following evidence in this case: The additional measures are effective. The specified
limit values of category C2, which are described in IEC 61800-3, are complied with.
2)
Characteristic curve: Power output of the device in dependence on the altitude of site at normal pressure
Transport temperature range
- 25 °C to + 70 °C
Transport climatic category
EN 60721-3-2
2 K 3
Storage temperature range
- 25 °C to + 55 °C
Storage climatic class EN 60721-3-1
1 K 4
Operation environment
industrial system
1)
Operation temperature range
min. 5 °C to max. 55 °C
(rated temperature 40 °C)
Operation climatic class EN 60721-3-3
3 K 3
Mounting height
2)
absolute altitude up to 2000 m
Humidity (operation)
EN 60721-3-3
relative humidity: 5 % to 85 % no condensation
and
absolute humidity: 1 g/m
3
to 25 g/m
3
Ionizing and non-ionizing radiation
measurable range
Vibration, shock and repetitive shock
EN 61800-5-1, section 5.2.6.4 Vibration test
max. 0.5 g during operation
Degree of pollution
EN 61800-5-1, table 6, Tab. 2
2
Altitude of site
Soutput
SNoutput
----------------------------
NOTICE!
Normally, non-conductive pollution occurs. Conductive pollution is unacceptable.
Conductive pollution can lead to the destruction of the device. The customer is re-
sponsible for destructions, which were caused by pollution due to conductive materi-
als or components.