Troubleshooting and Fault correction
Instruction handbook
b maXX
(BM4-F-)DIO/FIO-XX (Digital IO module)
Document No. 5.01046.06
63
10
3rd level
error messages
P0240 to P0244
Error in function module A to E
NOTE!
3rd level errors are only displayed in ProDrive separated by a decimal point from the
corresponding 2nd level error (refer to
e.g.:
Motor error 102: Group error find notch position
(2nd level)
Find notch position error 102.64: Drive moved more than 4 times delta angle.
(3rd level)
Error No.
Meaning
Reaction
Troubleshooting
0
reserved error
1
Module not identified
no
reaction
Check if the right module is plugged at the right posi-
tion
2
Identified module is not permitted at this posi-
tion
no
reaction
3
Digital output short-circuited or 24V supply not
connected to the DIO module
no
reaction
Check the cabling of the digital outputs
4
Invalid target parameter value caused by digital
input
no
reaction
Check the parameterization of the input channel
5
Direct PLC-IO access for this module not per-
mitted
no
reaction
Don’t select the module
6
Required module is missing, only for BM4100
active mains rectifier unit
IS
Connect the required module for operation with active
mains rectifier - see operation handbook
b maXX
4100
active mains rectifier unit
7
Module must not be used for actual active
mains rectifier unit mode or controller mode
no
reaction
8
Reserved
no
reaction
9
Too much Analog IO modules connected
no
reaction
More than 2 analog modules are not allowed
10
AIO-04: current < 4 mA
no
reaction
Current source not connected, disconnection or short-
circuit
11
AIO-04: current > 20 mA
no
reaction
Current source impress too much current
Summary of Contents for B MaXX 4000 Series