BM-F-DIO/FIO-XX for standard controller
Instruction handbook
b maXX
(BM4-F-)DIO/FIO-XX (Digital IO module)
Document No. 5.01046.06
Baumüller Nürnberg GmbH
24
4.2
Possible combinations function modules/option modules
Function modules
Option modules
BM4-F-ENC-XX
(e
ncode
r 1 for
motor contr
ol r
eco
mmended)
BM4-F
-ENC
-XX (encoder
2)
BM4-F
-AIO-01 (
analog I/O)
BM4-F
-AIO-02/0
3/04 (an
alog I/
O)
BM4-F
-DIO-X
X
(dig
ital I/O)
BM4-F
-F
IO-
XX (fast digit
al I/O)
BM4-F
-IEE-XX (
icremen
ta
l e
ncode
r emulatio
n)
BM4-F
-SIE-XX (
S
S
I e
ncod
er emulation)
BM4-F
-UME-
XX
(mains volt
age measur
ement)
BM4-O-SER-XX (Sercos s
lave)
BM4-O-PR
O-
01 (Pr
ofibus slave)
BM4-O-C
A
N-03 (
C
ANopen
slave
)
BM4-O-EC
T-
01 (
E
therCA
T
slave) fo
r controlle
r
BM4-O-PLK-01
(POWERLINK Co
ntrolled
Node) f
ür Regler
BM4-O-EIP-
01 (Ether
net-IP)
für R
egler
BM4-O-PLC-XX (SPS)
BM4-O-C
A
N-04* (
C
ANopen master
)
BM4-O-I
E
I-
XX*
(in
cr
ement
al co
unter modu
le)
BM4-O-ET
H-01
* (
E
therne
t)
BM4-O-ET
H-02
* (
E
therne
t +
CANopen master
)
BM4-O-EC
T-
01* (
E
th
erCA
T
slave) for
PLC
BM4-O-EC
T-
02* (
E
th
ernet + Ether
C
A
T
ma
ster
)
BM4-O-EC
T-
03* (
E
th
ernet + Ether
C
A
T
cluster
)
A
X
-
-
o
o
o
-
o
o
-
-
-
-
-
-
-
-
-
-
-
-
-
-
B
-
X
-
o
o
o
-
X
o
-
-
-
-
-
-
-
-
-
-
-
-
-
-
C
-
-
-
o
o
o
V
-
o
-
-
-
-
-
-
-
-
-
-
-
-
-
-
D
-
-
-
o
X
X
-
-
X
-
-
-
-
-
-
-
-
-
-
-
-
-
-
E
-
-
X
X
o
o
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
F
Controller unit
G
-
-
-
-
-
-
-
-
-
o
o
o
o
o
o
o
X X X X X X X
H
-
-
-
-
-
-
-
-
-
X
X
X
X
X
X X
o
-
o
o
o
o
o
J
-
-
-
-
-
-
-
-
-
-
P
P
-
-
-
-
o
o
o
o
-
-
-
K
-
-
-
-
-
-
-
-
-
-
P
P
-
-
-
-
o
o
o
o
o
o
o
L
-
-
-
-
-
-
-
-
-
-
P
P
-
-
-
-
o
o
o
o
o
o
o
M
-
-
-
-
-
-
-
-
-
-
P
P
-
-
-
-
o
o
o
o
o
o
o
S
teckka
rt
en
_Rev2
0
_e
X:
o:
P:
V:
-
*
preferred slot
Baumüller Nürnberg GmbH recommends, in order to reach the highest functional range, to
insert the plug-in modules into these slots.
possible slot
only if the preferred slot is occupied, we recommend in order to reach the highest functional
range, to insert the plug-in modules into this slot.
only possible, if on slot G or H a PLC module (PLC) is plugged and the PLC (and not the
controller) operates the communication to the field bus slave module.
dependent on controller hardware
not possible - card doesn’t work in this slot.
precondition for these cards is an inserted PLC module.
NOTE!
Only 2 analog outputs can be parametrized or linked even more than one AIO module
is plugged.