Heating Output Connector
The BATmode can supply a microphone heating integrated in the microphone disc of bat
bioacoustictechnology. The corresponding pin connection is presented in Table 8.
Table 8: Pin connection of the heating output connector
PIN
Description
Shell
Ground
Inner contact
12 - 19V DC
If the BATmode system is used for a simultaneous data acquisition at several measuring points, the
heating output can also be used to supply power to a USB hub. In this case, the heating of the
microphone discs is supplied with the USB heating cables.
Please note that microphone discs with a heating connection marked with "5V"
have to be operated only via USB heating cables and not via the heating output
of the BATmode. Violation may result in the destruction of the microphone
heater and equipment failure and damage, as well as data loss.
Do not use the heating output to supply microphone heating units or USB hubs
of other manufactures than bat bioacoustictechnology. The use of
unauthorized microphone discs, USB hubs and connection wires can cause
system failure, damage and the loss of data.
2.1.11
Power Supply Connector
The BATmode can be powered through a 12-19 V DC connector on the back panel (see figure 2). The
back panel DC connector is compatible with a 5.5 mm/OD (outer diameter) and 2.5 mm/ID (inner
diameter) plug, where the inner contact is +12-19 (±10%) V DC and the shell is GND. The maximum
current rating is 10 A.
Use only power supplies of bat bioacoustictechnology to power the BATmode.
The use of unauthorized power supplies und connection wires can cause system
failure, damage and the loss of data.