![BAT BATmode 2S User Manual Download Page 55](http://html1.mh-extra.com/html/bat/batmode-2s/batmode-2s_user-manual_2707882055.webp)
USER MANUAL BATMODE 2S/2S+ SYSTEM
46
Table 14: SMS remote commands
SMS text
System response
Reboot!
System reboots.
Shutdown!
System shuts down.
Caution: The system cannot be started again
remotely!
Send status!
Status SMS is sent to predefined number.
Send Mail!
Status mail is sent to predefined E-Mail address.
If no receiver address is defined and/or no Internet
connection is available, no action is conducted.
Send Mail to
max
(at)
moritz.com
!
Status mail is sent to
max
@
moritz.com
.
If no Internet connection is available, no action is
conducted.
Please note that since BATcontrol 2.1.0 this command
must also be terminated with an exclamation mark.
Start WIFI-Hotspot!
WIFI hotspot is started with the predefined settings.
Stop WIFI-Hotspot!
WIFI-Hotspot stops.
Connect WWAN!
Cellular connection will be established.
Disconnect WWAN!
Cellular connection will be disconnected.
Start monitoring!
Acoustic monitoring will be started ungated. That
means acoustic events will be recorded independent
of time of day.
Start monitoring:
11
:
00
-
14
:
00
!
Acoustic monitoring will be started gated by
recording period one. Consequently, acoustic events
will be recorded in this example only in the time
period between
11
:
00
and
14
:
00
o’clock
.
Start monitoring:
11
:
00-14
:
00
and
20
:
00
-
02
:
00
!
Acoustic monitoring will be started gated by
recording period one and two. Consequently,
acoustic events will be recorded in this example in the
time period between
11
:
00
and
14
:
00
o’clock as well
as
20:00
and
02:00
o’clock.
Start monitoring:
-20
/
10
!
Acoustic monitoring will be started relative to sunrise
and sunset. The daily recording of acoustic events
takes place in this example between
20
minutes
before sunset and
10
minutes after sunrise.
Stop monitoring!
Acoustic monitoring will be stopped.
Kill Recorder!
The acoustic monitoring is stopped by closing the
RECORDER software with a kill command. This allows
the monitoring to stop when the RECORDER software
displays an error message
Reset USG!
Terminates running monitoring and restarts the
UltraSoundGate from Avisoft by disconnecting it from
the power supply for some seconds.
Send MAC!
The MAC address of the BATmode is send to the
sender of the SMS.
Send IMEI!
The IMEI of the BATmode is send to the sender of the
SMS.
Send WIFI-IP!
The WIFI IP address of the BATmode is send to the
sender of the SMS.