18
ENG
6.2 Checks that can only be performed by an authorized tech
-
nician
Cut off the power supply before proceeding with any adjustment or
intervention.
Safety thermostat reset
Remove the backside of the appliance.
Identify the location of the thermostat, and press the
red button until you hear a mechanical warning sound
("click") that will confirm the closure of the contacts
(
fig. 13
).
The continuous intervention of the safety thermostat in
-
dicates a malfunction of the appliance.
(FIG. 13)
Motor thermal breaker
The motor thermal breaker is reset automatically and,
if this occurs, you should check the cleanliness of the
slits, and the regular and friction-free rotation of the
motor.
It is recommended to cut off the power supply.
(FIG. 14)
Water filter
If the appliance does not feed water anymore, check
the inlet filter of the solenoid which is located to the
back of the appliance as follows:
• close the water valve fitted upstream of the ap
-
pliance;
•
disconnect the water mains connection pipe;
• remove the filter located to the back of the solenoid
valve using pliers;
• remove any impurities and reposition it correctly
into its seat;
•
reconnect the pipe.
(FIG. 15)