9
ENG
5. Delta-T button. (For models with needle probe only)
6. Cooking/maintenance temperature button.
(For models with needle probe
only)
7. Cooking/maintenance Start/Stop button.
D. Display
The devices equipped with core needle probe have, in addition to the MAIN-
TENANCE function described in the previous paragraph, the option to cook at
fixed temperature or in Delta-T mode.
s
ettIng
the
cookIng
In
fIxed
temperature
mode
:
Connect the needle probe to the device. Press push-button
1
to turn on the
board display. The maintainer will show the default maintenance temperature
(before switch-on), or the last set temperature. Operate the keys
2
and
3
to
change the temperature.
(e.g.: 70°C)
Press the key
4
to set the core cooking temperature using keys
2
and
3
to
change this temperature.
(e.g. 75°C)
Press the key
6
to set the cooking chamber temperature using keys
2
and
3
to change this temperature.
(e.g.: 90°C)
Press the key
7
(
Start
) to start cooking. The maintainer sets to preheating
temperature “
PRE”
and emits an acoutic signal in the moment in which the
ideal cooking temperature is reached; now you can insert the product to be
cooked.
If the appliance operates with this setting, after being preheated, it cooks the
product at a temperature of 90 ° C until the internal temperature reaches 75
° C. Once this temperature is reached, the maintainer sets to “
HOLD”
(main-
tenance) at 70 ° C for an indefinite period of time.
s
ettIng
cookIng
wIth
d
elta
-t
system
:
The cooking in DT (Delta-T) mode allows cooking by maintaining a constant
difference in temperature between the temperature at the core of the product
and the temperature of the cooking chamber. For best results it is recom-
mended to start this cooking procedure with the appliance at room tempera-
ture.
Connect the needle probe to the device. Press push-button
1
to turn on the
board display. The maintainer will show the default maintenance temperature
(before switch-on), or the last set temperature. Operate the keys
2
and
3
to
change the temperature.
(e.g.: 70°C)
Press the key
4
to set the core cooking temperature using keys
2
and
3
to
change this temperature.
(e.g. 75°C)
Press the key
5
to set the DT cooking temperature using keys
2
and
3
to
change this temperature.
(e.g.: 25°C)
Insert the product in the maintainer and press the key
7
(
Start
) to start
cooking. If the appliance operates with this setting, it will cook the product
keeping a constant difference in temperature of 25° C between the core and
the cooking chamber until the internal temperature reaches 75 ° C. Once this
temperature is reached, the maintainer sets to “
HOLD”
(maintenance) at 70
° C for an indefinite period of time.
(FIG. 8)