6 Troubleshooting
If, after activating the machine by pressing “START” the run lamp is lit but all or part of the
motor is not running – check the following:
- Is the power connection correct?
- Are the cables in a good condition and properly laid?
- Are the fuses in the control panel closed?
- Is the motor overload protection in the control panel closed?
The turbine motor is not working.
- Has the blast chamber filled up with shot and blocked the blast wheel during transportation of the machine?
- Is the motor overload protection in the control panel closed?
The drive motor is not working.
- Is the fuse for the drive unit in the control panel closed?
- Are both (glass) fuses on the control circuit OK?
- Does the drive wheel turn easily when not connected to the drive motor?
The blast performance is too low.
- Is the blast wheel turning in the right direction?
- Has the blast wheel worn out?
- Has the shot cage been correctly adjusted?
- Has the shot cage worn out?
- Is the sieve in the shot compartment blocked?
- Is the shot valve blocked?
- Is the shot worn out? (Check the size of the balls)
MODUL 200
®
works for a short time and loses all the shot (carpeting effect).
- Is the blast wheel rotating in the correct direction?
- Has the blast wheel worn out?
- Has the shot cage been correctly adjusted?
- Has the shot cage been worn out?
- Do the rubber seals of the magnetic frame lie snugly with the floor?
- Have the rubber seals worn out?
- Is the height of the machine positioned too high?
- Is the belt of the turbine too lose? (The belt will slip on the pulleys and the blast wheel will not rotate quickly
enough).
- Is it possible to blast the floor? Check the condition.
- Is it dry and not too elastic or soft?
Summary of Contents for CONTEC MODUL 200
Page 1: ...MODUL 200 Mobile Shotblaster Instruction manual...
Page 24: ......