POLARIS PROFESSIONAL
- for Zone 1/21
POLARIS Panel PC Professional 15" up to 24"
Operation
Technical data subject to change.
04/2019
EN 51/68
8.
Operation
The device can be put into operation after the final check has been made.
The POLARIS series does not have any ON/OFF switch.
8.1
Operating system
The POLARIS series devices have the Windows 7 Ultimate or the Windows 10 IOT
Enterprise LTSB operating system pre-installed. According to the licence for Windows it is
not permissible to use this system as an office PC.
8.2
Commissioning Software
8.2.1
Windows 10 Iot Enterprise LRSB
The devices are delivered with active writing filter (UWF). This UWF prevents that changes
in the disk drive C: can be made.
To carry out changes the UWF must be deactivated. Moreover Command Prompt (CMD)
must be started as an administrator and „uwfmgr filter disable“ executed.
After a reboot the UFW is deactivated and changes in the system can be protected.
The turn on the UWF`s is proceed as follows:
Start the Command Prompt (CMD) as an administrator. After the reboot of the device the
command „uwfmgr filter enable“ activates the writing filter.
After the reboot the device is protected again.
Important: