Explosion protection and
approvals
POLARIS PROFESSIONAL
- for Zone 1/21
POLARIS Panel PC Professional 15" up to 24"
EN 8/68
Technical data subject to change.
04/2019
3.
Explosion protection and approvals
POLARIS Panel PC PROFESSIONAL
Type 17-71V1-….
ATEX
Ex protection type
II 2G Ex db eb mb q [ib op pr] IIC T4 Gb
II 2D Ex mb tb IIIC T120°C Db
-20 °C ≤ Ta ≤ 60 °C
Certification
IBExU 05 ATEX 1117 X
Standards
in accordance with
EMC Directive 2014/34/EU
EN 60079-0:2012+A11:2013
EN 60079-1:2014
EN 60079-5:2015
EN 60079-7:2015
EN 60079-11:2012
EN 60079-18:2015
EN 60079-28:2015
EN 60079-31:2014
IECEx
Ex protection type
Ex db eb qb [ib op pr] IIC T4
Ex tb IIIC T120 °C Db
Certification
IECEx IBE 11.0007X
Standards
in accordance with
EMC Directive 2014/34/EU
IEC 60079-0:2011
Edition: 6
IEC 60079-1:2014-06 Edition: 6
IEC 60079-5:2015
Edition: 4
IEC 60079-7:2015
Edition: 5
IEC 60079-11:2011
Edition: 6
IEC 60079-18:2015
Edition: 4
IEC 60079-28:2015
Edition: 2
IEC 60079-31:2013
Edition: 2
Special conditions
The intrinsically safe circuits and the enclosure are
galvanically connected. The equipotential bonding
must be guaranteed at the installation of the
intrinsically safe circuits.
High charging mechanisms at the operation surface
of the Visual units respectively accessories (for
example pneumatic particle transport) must be
excluded at the application. The degree of protection
(IP code) must be ensured by the installation of the
units in enclosures (IP code).