BH8-Series – User’s Manual
www.barrett.com
© 2007 Barrett Technology®, Inc.
Document: D3000, Version: AF.00
Page 52 of 82
Foil Strain
Gages
Idler Pulley
Idler Pulley
Shoulder Screw
Top Cable
Bottom
Cable
Figure 18 - Cable and Idler Pulley
Symptom:
The strain gage values do not follow the expected strain gage curves, shown in
Figure 28, while grasping.
Possible Solution:
1.
The finger cable pretension is not adjusted properly. Refer to Section 7.1 for instructions on
how to adjust.
2.
The strain gage balancing potentiometer needs to be readjusted. Refer to Section 7.4 for
instructions on how to adjust.
3.
Verify the cable is riding properly on the idler pulley, as shown in Figure 18.
4.
Verify idler pulley rotates freely on the shoulder screw. The shoulder screw should not be
tightened against the idler pulley. If so, loosen shoulder screw, shown in Figure 18, so the
idler pulley will move with cable motion.
5.
If the problem persists, contact Barrett Technology.
Symptom:
Only the fingertip closes when the entire finger should close (Premature
Breakaway).
Possible Solution:
1.
Verify there is no object blocking the inner link from moving.
2.
The finger was not opened completely. Restore that fingers OT, IVEL, IOFF, and IHIT to
their default values. Initialize the finger having the problem. The finger should now close
properly.
3.
If the problem persists, contact Barrett Technology.