![Barrett BH8 Series User Manual Download Page 14](http://html.mh-extra.com/html/barrett/bh8-series/bh8-series_user-manual_475712014.webp)
BH8-Series – User’s Manual
www.barrett.com
© 2007 Barrett Technology®, Inc.
Document: D3000, Version: AF.00
Page 12 of 82
1.2.3
Strain gage Joint-Torque Sensors
Barrett Technology offers a factory-installed torque sensor for the BH8-SERIES System. This
sensor measures the torque externally applied about the distal joint over a range of +/- 1 N-m.
This option uses strain gages to measures the differential tension in the “tendon” running through
each finger to the second joint. The information is processed in additional onboard circuitry when
this option is installed, it is accessed by requesting the present strain gage parameter. The strain
gage parameter represents the amount strain on the strain gage sensors. The strain gage values can
be calibrated by the customer to relate strain to joint torque. See Section 9.4 for more detailed
information on how the sensor works.
1.2.4
Control Software/Firmware Upgrades
Barrett Technology makes software and firmware upgrades periodically. Upgrades are available
for purchase or free of charge for customers of Barrett's subscription service. Refer to Barrett's
enclosed Warranty and Subscription Service Policy for more information.