7.3 Lubrication
Each BarrettHand™ unit has been lubricated and tested prior to shipping. Periodically, lubrication
must be reapplied to areas with high probability of lubricant flow. Use the grease syringe to apply
Mobil 1® Synthetic Grease (both included with the maintenance kit) to all exposed gear teeth at
the application points according to Figure 11 and the schedule in Table 6.
NOTE:
Issuing the following command to the hand will return the number of encoder counts, divided by 1000, on each
motor.
fget od
The number of joint cycles can be determined using the following conversions.
fingers 1,2,3:
(encoder counts)/17,500
spread
(encoder counts)/3,100
Table 6 - Lubrication Schedule
Application Point
Maintenance Cycle
Finger Worm Gears
5000 cycles
Finger Spur Gears
5000 cycles
Finger Motor Spur Gears
5000 cycles
Palm Spur Gears
5000 cycles
Motor Spur
Gear Lube
points
Palm Spur Gear
Lube points