27. Maintenance
6. Remove metal fixation bar from rear cover.
Both air filters (E) can be removed for cleaning or replacement.
C
E
E
Image 27-16
Air filter removal
How to clean!
1. Put the dirty air filter far away from the projector or preferable in another room.
2. Brush most of the dust off with a soft brush and/or blow dust away with compresses air.
Tip:
Always replace damaged and/or too dirty air filters by a new one.
How to reinstall the cleaned or new air filter
1. Place the air filters (A) on their place in the projector rear cover.
A
A
B
C
Image 27-17
Mounting the fixation bar
2. Place the metal fixation bar (B) on its place, slide it to the left and secure by tightening the 3 socket screws (C).
3. Place the metal fixation plate (D) on its place, slide it to the left and secure by tightening the 6 socket screws (E).
E
D
Image 27-18
Mounting the fixation plate
4. Reinstall the rear cover onto the projector and secure by turning the captive screws (A) half a turn clockwise.
190
R5976820 SLM R12+ PERFORMER 08/03/2005
Summary of Contents for SLM R12 Plus
Page 1: ...SLM R12 Performer Service Manual R9010170 R9010171 R5976820 00 08 03 2005...
Page 8: ...Table of contents 6 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 12: ...1 Safety 10 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 36: ...5 SLM R12 P Location of the Fans 34 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 56: ...8 Local Keypad LCD Display 54 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 82: ...11 Signal Input Selection R763850 R763851 80 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 90: ...13 Digital Inputs Backplane R763378 88 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 126: ...15 Lamp Power Supply R7633705 124 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 130: ...16 Start Pulse Generator SPG R763512 128 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 168: ...22 Infra Red Receiver Module R763261 166 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 174: ...24 Projector Tilt Switch R764240 172 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 178: ...25 Light Output Sensor R763294 176 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 182: ...26 Lamp Info Module R763295 180 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 258: ...27 Maintenance 256 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 274: ...29 Overview of the Electrical Diagrams 272 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 280: ...Index 278 R5976820 SLM R12 PERFORMER 08 03 2005...