8. Local Keypad & LCD Display
Info Display
LCD Display
Error Description
- L
ERROR(-2404)
LAMP POWER SUPPLY
LPS with I
2
C slave address 0x22: Mains voltage too low; must be
>180Vrms.
- L
ERROR(-2424)
LAMP POWER SUPPLY
LPS with I
2
C slave address 0x22: Error in LPS power circuits.
- L
ERROR(-24xx)
LAMP POWER SUPPLY
LPS with I
2
C slave address 0x22: Unknown LPS error.
- L
ERROR(-2501)
START PFC NOT OK
LPS with I
2
C slave address 0x22: Start-up of the PFC module failed.
- L
ERROR(-2502)
START LPS NOT OK
LPS with I
2
C slave address 0x22: Start-up of the LPS module failed.
- L
ERROR(-2503)
START BOOST NOT OK
LPS with I
2
C slave address 0x22: Start-up of the BOOST module failed.
- L
ERROR(-2506)
LAMP IGNITION FAILED
LPS with I
2
C slave address 0x22: Ignition of the lamp failed.
- L
ERROR(-2507)
LAMP VOLTAGE OUT RANGE
LPS with I
2
C slave address 0x22: The voltage at the lamp is too high.
- L
ERROR(-2508)
LAMP POWER OUT RANGE
LPS with I
2
C slave address 0x22: The power at the lamp is too high.
- L
ERROR(-2509)
OVERTEMP IN LPS
LPS with I
2
C slave address 0x22: Temperature in LPS is too high.
- L
ERROR(-2510)
HTSNK OVERTEMP LPS
LPS with I
2
C slave address 0x22: Heatsink temperature in LPS is too
high.
- L
ERROR(-2511)
AMBIENT OVERTEMP LPS
LPS with I
2
C slave address 0x22: Ambient temperature in LPS is too
high.
- L
ERROR(-2512)
FAN ERROR LPS
LPS with I
2
C slave address 0x22: Fan error.
- L
ERROR(-2701)
LAMP POWER SUPPLY
LPS with I
2
C slave address 0x28: Fuse F100 has blown up.
- L
ERROR(-2704)
LAMP POWER SUPPLY
LPS with I
2
C slave address 0x28: Mains voltage too low; must be
>180Vrms.
- L
ERROR(-2723)
LAMP POWER SUPPLY
LPS with I
2
C slave address 0x28: Error in LPS low voltage circuits.
- L
ERROR(-2724)
LAMP POWER SUPPLY
LPS with I
2
C slave address 0x28: Error in LPS power circuits.
- L
ERROR(-2725)
LAMP POWER SUPPLY
LPS with I
2
C slave address 0x28: Lamp has gone out and LPS still
running.
- L
ERROR(-2726)
LAMP POWER SUPPLY
LPS with I
2
C slave address 0x28: Lamp output short-circuited.
- L
ERROR(-2727)
LAMP POWER SUPPLY
LPS with I
2
C slave address 0x28: Output power out of range.
R5976820 SLM R12+ PERFORMER 08/03/2005
49
Summary of Contents for SLM R12 Plus
Page 1: ...SLM R12 Performer Service Manual R9010170 R9010171 R5976820 00 08 03 2005...
Page 8: ...Table of contents 6 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 12: ...1 Safety 10 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 36: ...5 SLM R12 P Location of the Fans 34 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 56: ...8 Local Keypad LCD Display 54 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 82: ...11 Signal Input Selection R763850 R763851 80 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 90: ...13 Digital Inputs Backplane R763378 88 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 126: ...15 Lamp Power Supply R7633705 124 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 130: ...16 Start Pulse Generator SPG R763512 128 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 168: ...22 Infra Red Receiver Module R763261 166 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 174: ...24 Projector Tilt Switch R764240 172 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 178: ...25 Light Output Sensor R763294 176 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 182: ...26 Lamp Info Module R763295 180 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 258: ...27 Maintenance 256 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 274: ...29 Overview of the Electrical Diagrams 272 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 280: ...Index 278 R5976820 SLM R12 PERFORMER 08 03 2005...