8. Local Keypad & LCD Display
Info Display
LCD Display
Error Description
- L
ERROR(-2001)
MAINS VOLTAGE TOO LOW
Mains voltage lower than minimum specified mains voltage.
- L
ERROR(-2002)
LAMP START FAILED
Unable to start the lamp.
- L
ERROR(-2003)
MAINS VOLTAGE TOO HIGH
Mains voltage higher than maximum specified mains voltage.
- L
ERROR(-2004)
LAMP GONE OUT
Lamp shut down, unknown error
- L
ERROR(-2040)
MAINS ERROR FROM LPS
There is no mains supply from LPS to SMPS
- L
ERROR(-2101)
LAMP POWER SUPPLY
LPS with I
2
C slave address 0x20: Fuse F100 is blown.
- L
ERROR(-2104)
LAMP POWER SUPPLY
LPS with I
2
C slave address 0x20: Mains voltage too low; must be
>180Vrms.
- L
ERROR(-2124)
LAMP POWER SUPPLY
LPS with I
2
C slave address 0x20: Error in LPS power circuits.
- L
ERROR(-21xx)
LAMP POWER SUPPLY
LPS with I
2
C slave address 0x20: Unknown LPS error
- L
ERROR(-2201)
START PC NOT OK
LPS with I
2
C slave address 0x20: Start-up of the PFC module failed.
- L
ERROR(-2202)
START LPS NOT OK
LPS with I
2
C slave address 0x20: Start-up of the LPS module failed.
- L
ERROR(-2203)
START BOOST NOT OK
LPS with I
2
C slave address 0x20: Start-up of the BOOST module failed.
- L
ERROR(-2206)
LAMP IGNITION FAILED
LPS with I
2
C slave address 0x20: Ignition of the lamp failed.
- L
ERROR(-2207)
LAMP VOLTAGE OUT RANGE
LPS with I
2
C slave address 0x20: The voltage at the lamp is too high.
- L
ERROR(-2208)
LAMP POWER OUT RANGE
LPS with I
2
C slave address 0x20: The power at the lamp is too high.
- L
ERROR(-2209)
OVERTEMP IN LPS
LPS with I
2
C slave address 0x20: Temperature in LPS is too high.
- L
ERROR(-2210)
HTSNK OVERTEMP LPS
LPS with I
2
C slave address 0x20: Heatsink temperature in LPS is too
high.
- L
ERROR(-2211)
AMBIENT OVERTEMP LPS
LPS with I
2
C slave address 0x20: Ambient Temperature in LPS is too
high.
- L
ERROR(-2212)
FAN ERROR LPS
LPS with I
2
C slave address 0x20: Fan error.
- L
ERROR(-2401)
LAMP POWER SUPPLY
LPS with I
2
C slave address 0x22: Fuse F100 has blown up.
48
R5976820 SLM R12+ PERFORMER 08/03/2005
Summary of Contents for SLM R12 Plus
Page 1: ...SLM R12 Performer Service Manual R9010170 R9010171 R5976820 00 08 03 2005...
Page 8: ...Table of contents 6 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 12: ...1 Safety 10 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 36: ...5 SLM R12 P Location of the Fans 34 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 56: ...8 Local Keypad LCD Display 54 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 82: ...11 Signal Input Selection R763850 R763851 80 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 90: ...13 Digital Inputs Backplane R763378 88 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 126: ...15 Lamp Power Supply R7633705 124 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 130: ...16 Start Pulse Generator SPG R763512 128 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 168: ...22 Infra Red Receiver Module R763261 166 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 174: ...24 Projector Tilt Switch R764240 172 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 178: ...25 Light Output Sensor R763294 176 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 182: ...26 Lamp Info Module R763295 180 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 258: ...27 Maintenance 256 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 274: ...29 Overview of the Electrical Diagrams 272 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 280: ...Index 278 R5976820 SLM R12 PERFORMER 08 03 2005...