Error Description
- L
ERROR(-2740)
LAMP POWER SUPPLY
LPS with I
2
C slave address 0x28: "Error mains" signal from SMPS
module has shut down the LPS module.
- L
ERROR(-2750)
LAMP POWER SUPPLY
LPS with I
2
C slave address 0x28: Over-temperature on heatsink mains
rectifier.
- L
ERROR(-2751)
LAMP POWER SUPPLY
LPS with I
2
C slave address 0x28: Over-temperature on heatsink PFC
and LPS primary.
- L
ERROR(-2752)
LAMP POWER SUPPLY
LPS with I
2
C slave address 0x28: Over-temperature in transformer LPS.
- L
ERROR(-2753)
LAMP POWER SUPPLY
LPS with I
2
C slave address 0x28: Over-temperature on heatsink LPS
secondary diode.
- L
ERROR(-2801)
START PFC NOT OK
LPS with I
2
C slave address 0x28: Start-up of the PFC module failed.
- L
ERROR(-2802)
START LPS NOT OK
LPS with I
2
C slave address 0x28: Start-up of the LPS module failed.
- L
ERROR(-2803)
START BOOST NOT OK
LPS with I
2
C slave address 0x28: Start-up of the BOOST module failed.
- L
ERROR(-2806)
LAMP IGNITION FAILED
LPS with I
2
C slave address 0x28: Ignition of the lamp failed.
- L
ERROR(-2807)
LAMP VOLTAGE OUT RANGE
LPS with I
2
C slave address 0x28: The voltage at the lamp is too high.
- L
ERROR(-2808)
LAMP POWER OUT RANGE
LPS with I
2
C slave address 0x28: The power at the lamp is too high.
- L
ERROR(-2809)
OVERTEMP IN LPS
LPS with I
2
C slave address 0x28: Temperature in LPS is too high.
- L
ERROR(-2810)
HTSNK OVERTEMP LPS
LPS with I
2
C slave address 0x28: Heatsink temperature in LPS is too
high..
- L
ERROR(-2811)
AMBIENT OVERTEMP LPS
LPS with I
2
C slave address 0x28: Ambient Temperature in LPS is too
high.
- L
ERROR(-2812)
FAN ERROR LPS
LPS with I
2
C slave address 0x28 :Fan error
- P
ERROR(-3001)
SMPS FAILED
The SMPS has unexpectedly shut down.
- P
ERROR(-3002)
SMPS START FAILED
Unable to start the SMPS.
- P
ERROR(-3003)
SMPS OUTPUT SHORTED
The output of the SMPS is shorted.
- P
ERROR(-3004)
TOP FAN ERROR
The Fan on top of the lamp is not working.
- P
ERROR(-3005)
ANODE FAN ERROR
The Fan at the anode of the lamp is not working.
50
R5976820 SLM R12+ PERFORMER 08/03/2005
Summary of Contents for SLM R12 Plus
Page 1: ...SLM R12 Performer Service Manual R9010170 R9010171 R5976820 00 08 03 2005...
Page 8: ...Table of contents 6 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 12: ...1 Safety 10 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 36: ...5 SLM R12 P Location of the Fans 34 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 56: ...8 Local Keypad LCD Display 54 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 82: ...11 Signal Input Selection R763850 R763851 80 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 90: ...13 Digital Inputs Backplane R763378 88 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 126: ...15 Lamp Power Supply R7633705 124 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 130: ...16 Start Pulse Generator SPG R763512 128 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 168: ...22 Infra Red Receiver Module R763261 166 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 174: ...24 Projector Tilt Switch R764240 172 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 178: ...25 Light Output Sensor R763294 176 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 182: ...26 Lamp Info Module R763295 180 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 258: ...27 Maintenance 256 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 274: ...29 Overview of the Electrical Diagrams 272 R5976820 SLM R12 PERFORMER 08 03 2005...
Page 280: ...Index 278 R5976820 SLM R12 PERFORMER 08 03 2005...