4. Lamp & Lamp House
6. Gently remove the xenon lamp together with the anode socket out of the Lamp House. Do not use excessive force upon the
xenon lamp. Normally the xenon lamp will easily slide out the cathode socket of the Lamp House.
Warning:
Supporting the xenon lamp with one hand while pulling it out with other hand prevents it from bumping against the
chassis of the Lamp House.
Image 4-22
7. Place the xenon lamp in its protective container or wrap the xenon lamp in a protective cloth and secure with two binders.
Image 4-23
Left: Xenon lamp wrapped in a protective cloth. Right: Xenon lamp captured in a protective container.
8. Remove the anode wire lug (reference 7 image 4-24) from the anode socket. Use for that two open ended spanners of 22 mm.
Hold the
fi
rst nut (reference 5) with one spanner while releasing the second nut (reference 9 image 4-24) with the other spanner.
Tip:
Place the
fl
at washer and the nut back on the rod after the lug is removed.
50
R5905963 PROMETHEUS SERIES 09/03/2015
Summary of Contents for Prometheus I
Page 1: ...Prometheus series Installation safety manual R5905963 00 09 03 2015 ...
Page 15: ...1 Safety PR Image 1 2 R5905963 PROMETHEUS SERIES 09 03 2015 11 ...
Page 92: ...5 Lenses lens holder 88 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Page 124: ...7 ICMP 120 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Page 130: ...8 Communicator Touch Panel 126 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Page 134: ...9 Starting up 130 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Page 152: ...10 Removal and installation of the projector covers 148 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Page 176: ...13 Specifications 172 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Page 186: ...14 Pin configurations 182 R5905963 PROMETHEUS SERIES 09 03 2015 ...