4. Lamp & Lamp House
5
Image 4-33
8. Install the side cover of the Lamp House and fasten the three quarter turn screws (reference 4 image 4-34) of the cover.
Note:
Please ensure that the quarter turn screws turning wires are
fl
ush with the cover or interference will occur while inserting
the Lamp House into the projector.
4
Image 4-34
9. Secure the xenon lamp cathode with the hexagon socket head cap screw (reference 1 image 4-35), spring washer (reference 2
image 4-35) and plain washer (reference 3 image 4-35). Fasten the screw with a torque of
5 Nm
(3,7 lbf*ft). Use a torque wrench
with a 5 mm Allen socket.
Caution:
Make sure that both pins (reference 11 image 4-35) of the cathode adapter remain engaged in the foreseen slots.
5 Nm
5 m
5 Nm
3
2
1
11
Image 4-35
C
AUTION
:
The “LAMP INFO” parameters which are stored on a chip inside the Lamp House MUST be updated
after each installation of an xenon lamp inside the Lamp House. Neglecting this update will result in poor
performance and short life time of the xenon lamp.
56
R5905963 PROMETHEUS SERIES 09/03/2015
Summary of Contents for Prometheus I
Page 1: ...Prometheus series Installation safety manual R5905963 00 09 03 2015 ...
Page 15: ...1 Safety PR Image 1 2 R5905963 PROMETHEUS SERIES 09 03 2015 11 ...
Page 92: ...5 Lenses lens holder 88 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Page 124: ...7 ICMP 120 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Page 130: ...8 Communicator Touch Panel 126 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Page 134: ...9 Starting up 130 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Page 152: ...10 Removal and installation of the projector covers 148 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Page 176: ...13 Specifications 172 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Page 186: ...14 Pin configurations 182 R5905963 PROMETHEUS SERIES 09 03 2015 ...