4. Lamp & Lamp House
4.11 Resetting the lamp parameters
C
AUTION
:
The “LAMP INFO” parameters MUST be updated after each installation of a xenon lamp inside the
Lamp House. Neglecting this update will result in poor performance and short life time of the xenon lamp.
For a new lamp, how to reset the values
1. While the
Lamp information
window is displayed, click on
Change lamp
(1).
A Reset lamp parameters selection window opens (2).
2. To get new lamps, click on
From new list
(3).
The lamp article and serial number opens (4).
3. Fill out the article number of the new lamp (5a)
Or,
click on
Select
(5b) to display a list of possible article numbers (6). Select a article number (7) and click
OK
(8).
The software will check if the entered article number is a valid number (9).
4. Fill out the serial number of the lamp (10).
5. Click
Reset lamp
(11).
For a used lamp, how to set back the original values
1. While the
Lamp information
window is displayed, click on
Change lamp
(1).
A
Reset lamp parameters
window opens (2).
2. To get history of the used lamps, click
from history
(3).
The Reset lamp history selection window opens (4).
3. Click on
Select
(5) to display a list of possible lamps (6).
4. Select the desired lamp (7) and click
OK
(8).
The article number and serial number of the selected lamp is added to the
Reset lamp parameters
window (10). The lamp run
time and number of strikes of this lamp are added in
Lamp parameter preview
(12).
5. The lamp parameters can be edited by the user under personnel maintenance and responsibility. If you want to change these
parameters, check the check box in front of
Edit lamp parameters
(11).
The current parameter
fi
elds become active (12).
6. Click in an input
fi
eld and change to the desired value.
7. Click
Reset lamp
(13).
66
R5905963 PROMETHEUS SERIES 09/03/2015
Summary of Contents for Prometheus I
Page 1: ...Prometheus series Installation safety manual R5905963 00 09 03 2015 ...
Page 15: ...1 Safety PR Image 1 2 R5905963 PROMETHEUS SERIES 09 03 2015 11 ...
Page 92: ...5 Lenses lens holder 88 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Page 124: ...7 ICMP 120 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Page 130: ...8 Communicator Touch Panel 126 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Page 134: ...9 Starting up 130 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Page 152: ...10 Removal and installation of the projector covers 148 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Page 176: ...13 Specifications 172 R5905963 PROMETHEUS SERIES 09 03 2015 ...
Page 186: ...14 Pin configurations 182 R5905963 PROMETHEUS SERIES 09 03 2015 ...